Ultra-fast x-ray tomography for multi-phase flow interface dynamic studies

Misawa, M.; Tiseanu, I.; Prasser, H.-M.; Ichikawa, N.; Akai, M.

The present paper describes the concept of a fast scanning X-ray tomograph, the hardware development, and measurement results of gas-liquid two-phase flow in a vertical pipe. The device uses 18 pulsed X-ray sources activated in a successive order. In this way, a complete set of 18 independent projections of the object is obtained within 38 ms, i.e. the measuring rate is about 250 frames per second. Finally, to evaluate the measurement capability of the fast X-ray CT, a wire-mesh sensor was installed in the flow loop and both systems were operated for the same two-phase flow simultaneously. Comparison of the time series of the cross section averaged void fraction from both systems showed sufficient agreement for slug flow at large void fractions, while the fast CT underestimated the void fraction of bubbly flow especially in low void fraction range. For the wire-mesh sensor, coerced deformation of slug bubble interface was found. Further hardware improvement is in progress to achieve better resolution with the fast X-ray CT scanner.

Keywords: Two-phase flow; X-ray tompgraphy; mesh sensors; bubble flow; slug flow

  • Kerntechnik 68 (2003) 3, pp. 85-90.