Coupling to System Codes

DYN3D / ATHLET 1)

DYN3D is coupled to the thermal-hydraulic system code ATHLET for analyzing more complex transients. Three different methods are used for coupling:

Internal coupling

 
  • Neutron kinetics of DYN3D
  • Thermal hydraulics of core and coolant system modelled by ATHLET

External coupling

 
  • Neutron kinetics and thermal hydraulics of core modelled by DYN3D
  • Thermal hydraulics of the remaining coolant system modelled by ATHLET
 

Parallel coupling

 
  • Neutron kinetics and thermal hydraulics of core modelled by DYN3D
  • Thermal hydraulics of the core and the coolant system modelled by ATHLET
1)   ATHLET is developed by the Gesellschaft für Anlagen- und Reaktorsicherheit (GRS).

DYN3D / RELAP5

DYN3D is coupled to the thermal-hydraulic system code RELAP5 by the Institute of Physics and Power Engineering, Obninsk. The method of internal coupling is used.

Validation of Coupled Codes

  • Comparison with other codes
  • 5th Dynamic AER Benchmark: Main Steam Header Break in a NPP with VVER-440 Reactor
PDF-ICON(1)
  • 6th Dynamic AER Benchmark: Main Steam Line Break in a NPP with VVER-440 Reactor
PDF-ICON(2)
  •  OECD Main Steam Line Break Benchmark for TMI-1
PDF-ICON(3)
  • OECD/NEA VVER-1000 Coolant Transient Benchmark Phase 2 (V1000CT2): Main Steam Line Break Analysis
 
  • Comparison to measurements and with other codes
  • Turbine load drop test in the nuclear power plant (NPP) Loviisa-1 with VVER-440 reactor (EU PHARE Project SRR 1/95)
(4)
  • Start-up test: Turning-off one from two feedwater pumps in the NPP Balakovo-4 withVVER-1000 reactor (EU PHARE Project SRR 1/95) 
(5)
  • Start-up test: Switch-off of one of three working main coolant pumps at 65 % power at the VVER-1000 NPP Kozloduy-6 (EU Project VALCO)
PDF-ICON(6)
  • OECD BWR  Turbine Trip Benchmark (NPP Peach Bottom)
PDF-ICON(7)
  • OECD/NEA VVER-1000 coolant transient benchmark Phase 1 (V1000CT1):  Start-up test: Switch-on of one main coolant pump at 30 % power at the VVER-1000 NPP Kozloduy-6
PDF-ICON(8)

NPP Balakovo-4:
Comparison of the results of the DYN3D/ATHLET calculations with the measured power behaviour. Influence of the constant and dynamic heat transfer coefficient (HTC) calculated by the DYN3D gas gap model.


URL of this article
https://www.hzdr.de/db/Cms?pOid=11789


Links of the content

(1) https://www.hzdr.de/db/Cms?pOid=25008
(2) https://www.hzdr.de/db/Cms?pOid=25009
(3) https://www.hzdr.de/db/Cms?pOid=25010
(4) https://www.hzdr.de/FWS/FWSS/dyn3d/annual2t.pdf
(5) https://www.hzdr.de/FWS/FWSS/dyn3d/annual2t.pdf
(6) https://www.hzdr.de/db/Cms?pOid=25011
(7) https://www.hzdr.de/db/Cms?pOid=25012
(8) https://www.hzdr.de/db/Cms?pOid=25013