Cyclotrons for radionuclide production in Germany


Number of cyclotrons: 26
Index by : Manufacturers

Manufacturer:

Ion Beam Applications s.a. (IBA), Belgium

http://www.iba-worldwide.com
PET-Zyklotron Type of cyclotron:
CYCLONE 18/9

Particles and energies:
negative ions
p = 18 MeV
d = 9 MeV

CYCLONE 18/9 with beam transport line (BTL)
in the Forschungszentrum Dresden-Rossendorf
Source: Forschungszentrum Dresden-Rossendorf

CYCLONE 18/9

installed in in operation since
Radiopharmazie
Herz- und Diabeteszentrum NRW Bad Oeynhausen

1994
Forschungszentrum Dresden-Rossendorf,
PET-Zentrum Rossendorf

1996
Nuklearmedizin
Universitätsklinikum-GHS-Essen

1999


CYCLONE 3 Type of cyclotron:
CYCLONE 3 (15O-Generator)

Particles and energies:
negative ions
d = 3.5 MeV

CYCLONE 3
Source: IBA-News, 1990

CYCLONE 3

installed in: in operation since:
Rudolf-Virchow-Krankenhaus Berlin 2000

Manufacturer:

Scanditronix Medical AB, Sweden

(Scanditronix Medical AB is part of IBA, Belgium since 1998)
Scanditronix MC32 Type of cyclotron:
MC16
Particles and energies:
p = 17.2 MeV
d = 8.3 MeV
3He2+ = 12.4 MeV
4He2+ = 16.5 MeV

MC32NI
Particles and energies:
negative ions
p = 16-32 MeV
d = 8.5-16 MeV

MC35
Particles and energies:
p = 7.5-35 MeV
d = 3.8-18 MeV
3He2+ = 5.6-47 MeV
4He2+ = 7.5-35 MeV

Scanditronix MC32NI
Source: Scanditronix information
Type of cyclotron: installed in: in operation since:
MC16
Max-Planck-Institut für Neurologische Forschung Köln 1987
MC32NI
Deutsches Krebsforschungszentrum (DKFZ) Heidelberg 1992
MC35
Medizinische Hochschule Hannover 1977

Manufacturer:

General Electric (GE), Sweden

GE: PETtrace Type of cyclotron:
PETtrace

Particles and energies:
negative ions
p = 16.5 MeV
d = 8.4 MeV

GE: PETtrace
Source: GE information

PETtrace

installed in: in operation since:
Universitätsklinikum Tübingen 1995
Euro-PET GmbH Freiburg 1996
Forschungszentrum Jülich 1997
Universitätsklinikum Leipzig 2002
Medizinische Universitätsklinik Ulm 2002
EUROPET ZYKLOTRON BERLIN GmbH, Berlin 2003

Manufacturer:

CTI Inc., USA

CTI: RDS 111 Type of cyclotron:
RDS 112
Particles and energies:
negative ions
p = 11 MeV

Type of cyclotrons:
RDS 111
Particles and energies:
negative ions
p = 11 MeV

CTI: RDS 111
Source: CTI lecture

RDS 112

installed in: in operation since:
Klinikum Rechts der Isar München 1993
Charite, Campus Mitte, Berlin 1998
Westdeutsche Cyclotron GmbH Bonn 1999

RDS 111
installed in: in operation since:
PET-Zentrum der Zentralklinik GmbH Bad Berka 1997
Universitätsklinikum der
Rheinisch-Westfälischen Technischen Hochschule Aachen

1998
PET-NET GmbH Erlangen 1999
Klinik und Poliklinik für Nuklearmedizin
der Westfälischen Wilhelms-Universität Münster

2000

Manufacturer:

The Cyclotron Corporation (TCC), USA

The firm does not exist anymore. CTI Inc., USA is the successor firm.
TCC: CP42H in Karlsruhe Type of cyclotron:
CV 28
Particles and energies:
p = 2-24 MeV
d = 3-14 MeV
3He2+ = 5-36 MeV
4He2+ = 6-28 MeV

CP42H
Particles and energies:
negative ions
p = 15-42 MeV

TCC: CP42H in the Forschungszentrum Karlsruhe,
known as Karlsruher Zyklotron (KAZ)
Source: Forschungszentrum Karlsruhe
Type of cyclotron: installed in: in operation since:
CV 28
Universitätsklinikum Essen 1975
Forschungszentrum Jülich 1976
CP42H
ZAG Zyklotron AG, Karlsruhe 1984

Manufacturer:

Japan Steel Works Ltd. (JSW), Japan

Type of cyclotron:
BC 1710
Particles and energies:
p = 17 MeV
d = 10 MeV

BC 1710

installed in: in operation since:
Forschungszentrum Jülich 1987

Manufacturer:

Philips, The Netherlands

Philips 140/IV-cyclotron in the Universitätsklinikum Hamburg-Eppendorf Type of cyclotron:
Philips 140/IV
Particles and energies:
p = 4-30 MeV
d = 2-16 MeV
3He2+ = 6-42 MeV
4He2+ = 6-36 MeV
Philips 140/IV-cyclotron in the Universitätsklinikum Hamburg-Eppendorf
Source: Universitätsklinikum Hamburg-Eppendorf

Philips 140/IV

installed in: in operation since:
Universitätsklinikum Hamburg-Eppendorf 1968

Manufacturer:

ADVANCED CYCLOTRON SYSTEMS Inc. (ACSI), Canada

http://www.advancedcyclotron.com
ACSI-Zyklotron1 Type of cyclotron:
TR19/9
Particles and energies:
negative ions
p = 19 MeV
d = 9 MeV
TR19/9
Source: ACSI, Canada

TR19/9

installed in: in operation since:
ZAG Zyklotron AG, Karlsruhe 2008