Experiments

Air/water experiments in vertical test sections

The test section circuit and the compressed air system of the test facility are used for air/water experiments at the vertical test sections.

The test section pump supports the water from the steam drum into the lower part of the both test sections, which can be blocked separately. The required mass flow is adjusted with the help of three parallel control valves and with the frequency converter of the test section pump. The injection of the gas phase is performed by specific injection heads also in the lower leg of the test section. The necessary volume flow is made available from the six parallel compressed air controllers. The measurements are carried out with specific wire-mesh sensors, which are installed at the upper end of the test sections.

A detailed description of the single elements of the test section circuit, as well as of the compressed air system can be obtained by clicking the respective components. The navigation point "Facility" contains explanations for the whole test facility.

description of the steam drum description of the vertical test section description of the test section pump description of the compressed air system

Anlagenschema_Luft/Wasser Experimente in vertikalen Teststrecken

The following experimental matrixes provide measurements of ten series of measurements. The dark fields emphasise the points measured in each case. The axes indicate the superficial velocities of the fluid and gas phases. Below the experimental matrixes, the most important test conditions of the experiments are registered.

Test section DN 200; series: LD01

Experimental matrix test section DN200 run L20

Boundary conditions:

  • Central air injection with the injection head type K through 60 orifices with a diameter of 6 mm
  • Measurement with two low temperature wire-mesh sensors (64 x 64 electrodes)
  • Distance between the air injection and the measurement plane of the first sensor: 7,606 mm
  • Pressure in the test section: approx. 0.1 MPa
  • Temperature in the test section: 15 - 25 °C

Test section DN 200; series: LD02

Experimental matrix testsection DN200 run L20 type I

Boundary conditions:

  • Central air injection with injection head type I through 152 orifices with a diameter of 0.8 mm
  • Measurement with two low temperature wire-mesh sensors (64 x 64 electrodes)
  • Distance between the air injection and the measurement plane of the first sensor: 7,606 mm
  • Pressure in the test section: approx. 0.1 MPa
  • Temperature in the test section: 20 - 30 °C

Test section DN 50; series: LD03 - LD07

Experimental matrix test section DN50 run L20 postions ACDF

Boundary conditions:

  • Central air injection with the injection head type K through 8 orifices with a diameter of 4 mm
  • Measurement with two low temperature wire-mesh sensors (16 x 16 electrodes)
  • Investigation of all measurement points at distances between the air injection and the measurement plane of the first sensor of: 100; 1,600; 3,100 and 7,910 mm
  • Pressure in the test section: approx. 0.1 MPa
  • Temperature in the test section: 25 - 35 °C

Test section DN 50; series: L03, L04

Experimental matrix test section DN50 run L03/L04 injection head type I

Boundary conditions:

  • Central air injection with the injection head type I through 24 orifices with a diameter of 0,8 mm
  • Measurement with one low temperature wire-mesh sensor (16 x 16 electrodes)
  • Distance between the air injection and the measurement plane of the sensor: 7,910 mm
  • Pressure in the test section: approx. 0.1 MPa
  • Temperature in the test section: 20 - 30 °C

Test section DN 50; series: L05

Experimental matrix test section DN50 run L03/L04 injection head type K position F

Boundary conditions:

  • Central air injection with the injection head type K through 8 orifices with a diameter of 4 mm
  • Measurement with two high temperature wire-mesh sensors (16 x 16 electrodes)
  • Distance between the air injection and the measurement plane of the sensor: 7,910 mm
  • Pressure in the test section: approx. 0.1 MPa
  • Temperatures in the test section: 27 - 29 °C

Test section DN 200; series: L11

Testmatrix DN200 L11 gas injection head type I position F obstacle

Boundary conditions:

  • Central air injection with the injection head type I through 152 orifices with a diameter of 1 mm
  • Measurement with one high temperature wire-mesh sensor (64 x 64 electrodes)
  • Measurement with half-moon shaped obstacle: distance from the measurement plane: 10; 15; 20; 40; 80; 160; 250; 520 mm below or above of the sensor
  • Distance between the gas injection and the measurement plane of the wire-mesh sensor: obstacle above: 5,110 mm and obstacle below: 6,170 mm, respectively
  • Pressure in the test section: approx. 0.1 MPa
  • Temperature in the test section: 23 - 37 °C