The OPC readout via MBS

MBS can read some OPC data containing information about the status of some ELBE parameters. This is done using a shared memory. This shared memory is allocated and written by the program opc2shm which can be found on the MBS working directory ("mbsrun/nng/"). The source code can be found in "urania:/home/ntofdaq/c/shmem/".

This program has to be started from one of the power PCs rio3 or rio6 (using ./opc2shm). By setting the "opcreadout(1)" value in the corresponding "setup_vme_1.ini(2)" the OPC data will be read from the shared memory into the data stream, i.e., the listmode file.


Content from Sidebar

Contact

Dr. Roland Beyer

Beam line scientist, radiation protection officer FWK
Nuclear Physics
roland.beyer@hzdr.de(3)
Phone: +49 351 260 3281


URL of this article
https://www.hzdr.de/db/Cms?pOid=26642


Links of the content

(1) https://www.hzdr.de/db/Cms?pOid=25472#opcreadout
(2) https://www.hzdr.de/db/Cms?pOid=25472#vme1
(3) mailto:roland.beyer@hzdr.de
(4) https://www.hzdr.de/db/Cms?pNid=1656