Kühn, J.; Bürger, M.; Frahm, A.; Jankowiak, A.; Kamps, T.; Klemz, G.; Kourkafas, G.; Neumann, A.; Ohm, N.; Schmeißer, M.; Schuster, M.; Völker, J.; Murcek, P.; Teichert, J.

The initial commissioning of the Superconducting RF (SRF) photoinjector is achieved with a Cu photocathode due to its robustness with respect to interactions with the SRF cavity of the injector. Here we present the preparation and characterization of a Cu photocathode plug and the diagnostics to insert the photocathode in the back wall of the SRF cavity. A polycrystalline bulk Cu plug was polished, particle free cleaned and characterized by x-ray photoelectron spectroscopy. During the transfer of the photocathode insert into the gun module the whole process was controlled by several diagnostic tools monitoring the insert position as well as RF, vacuum and cryogenic signals. We discuss the challenges of the photocathode transfer into an SRF cavity and how they can be tackled.

Keywords: electron source; photocathode; Cu; SRF gun; superconducting RF

Related publications

  • Poster
    9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada
  • Open Access Logo Contribution to proceedings
    9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada
    Proceedings of the 9th International Particle Accelerator Conference IPAC´18, Genf: JACoW, 1247-1250
    DOI: 10.18429/JACoW-IPAC2018-TUPMF002

Permalink: https://www.hzdr.de/publications/Publ-27493