magnetic systems: electromagnets supplying a transverse magnetic field
magnet 1: length of uniform field 320 mm
maximum field strength 0.45 T
magnet 2: length of uniform field: 1100 mm
maximum field strength: 0.8 T
range of dimensionless parameters:
Reynolds number Re up to about 105
Hartmann number Ha up to 2700 (magnet 1)
up to 4800 (magnet 2)
Interaction parameter N 800 (magnet 1, vSo = 0.1 m/s)
2500 (magnet 2, vSo = 0.1 m/s)