Spatial Resolution of Thin-Walled High-Pressure Drift Tubes
Spatial Resolution of Thin-Walled High-Pressure Drift Tubes
Davkov, V. I.; Gregor, I.; Haas, D.; Mouraviev, S. V.; Myalkovskiy, V. V.; Naumann, L.; Peshekhonov, V. D.; Rembser, C.; Rufanov, I. А.; Russakovich, N. А.; Senger, P.; Smirnov, S. Y.; Tikhomirov, V. O.
A small prototype detector based on high pressure thin-walled tubes (straws) has been developed and its parameters have been studied on a bench at JINR, Dubna, and SPS at CERN. The inner diameter of the straws is 9.53 mm. The pressure of the active gas mixture Ar/CO2 (80/20) has been varied from 1 to 5 bar. The best spatial resolution achieved in this pressure range is ~40 μm. Both the high efficiency and high rate capability are retained.
Keywords: Coordinate Detector; High Pressure; Thin-Walled Drift Tube; Straw; Spatial Resolution
-
Nuclear Instruments and Methods in Physics Research A 634(2011), 5-7
DOI: 10.1016/j.nima.2010.10.045
Cited 6 times in Scopus
Permalink: https://www.hzdr.de/publications/Publ-14765
Publ.-Id: 14765