CW Beam Stability Analysis in Time and Frequency Domain
Kuntzsch, M.; Lehnert, U.; Schurig, R.; Teichert, J.; Gensch, M.; Kovalev, S.; Green, B.; Michel, P.
The superconducting quasi CW Linac ELBE has been characterized in terms of energy and timing stability. The measurement results presented show a combination of a laser-based bunch arrival-time measurements (BAM), a fast beam position monitor (BPM) readout with single bunch resolution and a compression monitor (BCM) based on a fast pyro-electric detector. By changing the bunch compression factor a separation and identification of jitter sources has been achieved. The quasi CW mode of operation enables frequency domain data analysis with high dynamic range, which gives a better understanding of the main sources of jitter. Experimental results for both injectors (thermionic DC, superconducting RF) are presented.
Keywords: ELBE Synchronization Timing Stability BAM
Related publications
- DOI: 10.17815/jlsrf-2-58 is cited by this (Id 21140) publication
-
Contribution to proceedings
IBIC 2014 - 3rd International Beam Instrumentation Conference, 14.-18.09.2014, Monterey, USA
Proceedings of IBIC 2014 -
Poster
IBIC 2014 - 3rd International Beam Instrumentation Conference, 14.-18.09.2014, Monterey, USA
Permalink: https://www.hzdr.de/publications/Publ-21140
Publ.-Id: 21140