Publications Repository - Helmholtz-Zentrum Dresden-Rossendorf

1 Publication

Versuchsanlage ROCOM zur Untersuchung der Kühlmittelvermischung in Druckwasserreaktoren - Ergebnisse quasistationärer Vermischungsexperimente

Grunwald, G.; Höhne, T.; Kliem, S.; Prasser, H.-M.; Richter, K.-H.; Rohde, U.; Weiß, F.-P.

The test facility ROCOM (Rossendorf Coolant Mixing Model) has been built for the investigation of coolant mixing processes in the reactor pressure vessel of pressurised water reactors (PWR). ROCOM is a 1:5 model of the German PWR KONVOI and has been designed for a wide range of different mixing scenarios. ROCOM disposes of four loops with fully controllable coolant pumps. The test facility is operated with demineralised water. For the investigation of mixing, tracer solution (water labelled with salt) is injected into the facility. The transient distribution of the electrical conductivity is is measured at different positions of the flow path by means of wire-mesh sensor technique with high resolution in space and time. The measured conductivity is transformed into a dimensionless mixing scalar.
The mixing at quasi-stationary conditions (constant loop mass flow rates) has been investigated in the presented experiments. That concerned nominal operation conditions, the operation with a reduced number of loops and the investigation of cold-water transients with running pumps and conditions of developed natural circulation. In special experimental series, the reproducibility of the results at identicla boundary conditions within the confidence intervalls has been shown. Further, the influence of various factors on the mixing has been investigated. This included the pressure losses at the core bottom plate, the global coolant flow level and the influence of the loop flow rate on the perturbed sector at the core inlet. An analysis of the measurement error of the used measurement technique completes the report.

Keywords: pressurised water reactors; pressure vessel; coolant flow; turbulent mixing; test facility; stationary flow; forced flow; natural circulation; conductivity measurement; wire-mesh sensor

  • Open Access Logo Wissenschaftlich-Technische Berichte / Forschungszentrum Rossendorf; FZR-348 Juli 2002
    ISSN: 1437-322X

Downloads

Permalink: https://www.hzdr.de/publications/Publ-4974