1 PublicationApplication of high resolution gamma ray tomography to the measurement of gas hold-up distributions in a stirred chemical reactor
Hampel, U.; Hristov, H. V.; Bieberle, A.; Zippe, C.
We employed high resolution gamma ray tomography to measure radial and axial phase distributions in a laboratory type chemical reactor with a gas inducing turbine stirrer. Therefore, we used a recently developed gamma ray CT system which is operated with a Cs-137 source and a detector that achieves approximately 2 mm spatial resolution. The measured data has been compared to computational fluid dynamics predictions obtained with CFX 10.0.
Keywords: gamma ray tomography; stirred reactor; two-phase flow measurement; CFD simulation
-
Flow Measurement and Instrumentation 18(2007), 184-190
DOI: 10.1016/j.flowmeasinst.2007.06.001
Cited 49 times in Scopus
Permalink: https://www.hzdr.de/publications/Publ-9418