Contact

Porträt Dr. Kögler, Toni; FWMP

Dr. Toni Kögler

Group Leader, Prompt Gamma-Ray based Treatment Verification
Medical Radiation Physics
t.koeglerAthzdr.de
Phone: +49 351 4587414
+49 351 260 3614

Forschungsplattform

Vorschau-Bild

Partner

Vorschau-Bild
Vorschau-Bild
Vorschau-Bild
Vorschau-Bild
Vorschau-Bild

Weitere Informationen

Patients and physicians may contact the University Proton Therapy Dresden hotline at 0351 458 15693 (Monday to Friday from 9am to 11am and 1pm to 3pm) or via via e-mail: protonentherapie@uniklinikum-dresden.de

Vorschau-Bild

List of Publications

 
 

Articles in refereed journals

2024

Characterisation of a high granularity multi-channel prompt γ-ray detection system prototype for proton range verification based on the PETsys TOFPET2 ASIC

Novgorodova, O.; Glatte, A.; Hentges, R.; Kögler, T.; Lutz, B.; Römer, K.; Teichmann, T.; Weinberger, D.; Straessner, A.

Involved research facilities

Related publications


2023

Hybrid treatment verification based on prompt gamma-rays and fast neutrons: Multivariate modelling for proton range determination

Schellhammer, S.; Meric, I.; Löck, S.; Kögler, T.

Involved research facilities

  • OncoRay

A hybrid multi-particle approach to range assessment-based treatment verification in particle therapy

Meric, I.; Alagoz, E.; Hysing, L.; Kögler, T.; Lathouwers, D.; Lionheart, W.; Mattingly, J.; Obhodas, J.; Pausch, G.; Pettersen, H.; Ratliff, H.; Rovituso, M.; Schellhammer, S.; Setterdahl, L.; Skjerdal, K.; Sterpin, E.; Sudac, D.; Turko, J. A. B.; Ytre-Hauge, K.

Involved research facilities

Related publications


2022

Multivariate statistical modelling to improve particle treatment verification: Implications for prompt gamma-ray timing

Schellhammer, S.; Wiedkamp, J.; Löck, S.; Kögler, T.


2020

Detection Systems for Range Monitoring in Proton Therapy: Needs and Challenges

Pausch, G.; Berthold, J.; Enghardt, W.; Römer, K.; Straessner, A.; Wagner, A.; Werner, T.; Kögler, T.

Involved research facilities

Related publications


2019

Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery

Werner, T.; Berthold, J.; Hueso-Gonzalez, F.; Koegler, T.; Petzoldt, J.; Roemer, K.; Richter, C.; Rinscheid, A.; Straessner, A.; Enghardt, W.; Pausch, G.

Involved research facilities

Related publications

Abstracts in refereed journals

2020

First systematic clinical study on detection of anatomical changes in PT using prompt-gamma imaging

J. Berthold; A. Jost; C. Khamfongkhruea; J. Petzoldt; J. Thiele; T. Hölscher; P. Wohlfahrt; G. Pausch; G. Janssens; J. Smeets; C. Richter


First-in-man validation of CT-based stopping-power prediction using prompt-gamma range verification

J. Berthold; C. Khamfongkhruea; A. Jost; J. Petzoldt; J. Thiele; T. Hölscher; P. Wohlfahrt; C. Hofmann; G. Pausch; G. Janssens; J. Smeets; C. Richter


2019

Range verification in proton therapy: Can prompt-gamma imaging identify the source of deviation?

C. Khamfongkhruea; G. Janssens; J. Petzoldt; J. Smeets; G. Pausch; C. Richter


2017

Sensitivity evaluation of prompt γ-ray based range verification with a slit camera

L. Nenoff; M. Priegnitz; A. Trezza; J. Smeets; G. Janssens; F. Vander Stappen; L. Hotoiu; D. Prieels; W. Enghardt; G. Pausch; C. Richter


2016

First clinical application of a prompt gamma based in vivo proton range verification using a knife-edge slit camera

C. Richter; G. Pausch; S. Barczyk; M. Priegnitz; I. Keitz; J. Thiele; J. Smeets; F. Vander Stappen; L. Bombelli; C. Fiorini; L. Hotoiu; I. Perali; D. Prieels; W. Enghardt; M. Baumann


Prompt gamma imaging of passively shaped proton fields with a knife-edge slit camera

M. Priegnitz; S. Barczyk; I. Keitz; S. Mein; F. Vander Stappen; G. Janssens; L. Hotoiu; J. Smeets; F. Fiedler; D. Prieels; W. Enghardt; G. Pausch; C. Richter


Clinical applicability of the Compton camera for Prompt y-ray Imaging during proton therapy

H. Rohling; M. Priegnitz; S. Schöne; A. Schumann; W. Enghardt; C. Golnik; F. Hueso-Gonzalez; T. Kormoll; G. Pausch; J. Petzoldt; K. Römer; F. Fiedler


2015

Prompt-Gamma-Imaging für die Echtzeit-Reichweiten-Verifikation in der Protonentherapie: Auf dem Weg zur klinischen Implementierung

S. Barczyk; C. Golnik; M. Priegnitz; F. Vander Stappen; G. Janssens; J. Smeets; E. Clementel; L. Hotoiu; J. O. de Xivry; M. Baumann; W. Enghardt; F. Fiedler; M. Krause; D. Prieels; G. Pausch; C. Richter


2013

Untersuchung von Szintillationsdetektoren für Prompt Gamma Imaging Systeme zur Verifikation der Dosisdeposition in der Protonentherapie

K. Römer; J. Petzoldt; G. Pausch; H. Rohling; N. Hertel; F. Fiedler

  • Open Access Logo Abstract in refereed journal
    Medizinische Physik 2013 (2013), 322-323
    ISSN: 978-3-9816002-1-6

GEANT4 Simulationen zur Optimierung einer Compton Kamera für die In-vivo Dosimetrie

H. Rohling; W. Enghardt; N. Hertel; T. Kormoll; G. Pausch; F. Fiedler

  • Abstract in refereed journal
    Medizinische Physik 2013 (2013), 710

Proceedings

2019

Enhanced Fiberoptical Dosimetry through Time-resolved Single Photon Detection in Proton Fields

T. Kormoll; E. R. van der Graaf; M. J. van Goethem; M. J. Gonzalez Torres; P. Lachmann; G. Pausch; A. Majchrowski; K. Makarevich; D. Weinberger; K. Zuber; T. Teichmann

  • Contribution to proceedings
    2019 IEEE Nuclear Science Symposium & Medical Imaging Conference, 26.10.-02.11.2019, Manchester, UK
    Proceedings of the 2019 IEEE Nuclear Science Symposium & Medical Imaging Conference

2018

Developing a Single Plane Compton Camera for Radionuclide Imaging

B. Deneva; K. Roemer; A. Wagner; W. Enghardt; G. Pausch; T. Koegler

  • Open Access Logo Contribution to proceedings
    49. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik, 19.-22.09.2018, Nürnberg, Deutschland

Range verification in proton therapy by prompt gamma-ray timing (PGT): Steps towards clinical implementation

T. Werner; J. Berthold; W. Enghardt; F. Hueso González; T. Kögler; J. Petzoldt; C. Richter; A. Rinscheid; K. Römer; K. Ruhnau; J. Smeets; J. Stein; A. Straessner; A. Wolf; G. Pausch


2017

A novel scheme of Compton imaging for nuclear medicine

G. Pausch; C. Golnik; A. Schulz; W. Enghardt


2016

Commissioning of a Compton Camera for particle beam range monitoring

P. G. Thirolf; S. Aldawood; M. Böhmer; J. Bortfeldt; I. Castelhano; G. Dedes; W. Enghardt; F. Fiedler; R. Gernhäuser; C. Golnik; S. Helmbrecht; F. Hueso-González; H. V. D. Kolff; T. Kormoll; C. Lang; S. Liprandi; L. Maier; T. Marinšek; A. Miani; G. Pausch; J. Petzoldt; M. Pocevicius; K. Römer; D. R. Schaart; I. Valencia-Lozano; K. Parodi

  • Contribution to proceedings
    2016 IEEE Nuclear Science Symposium and Medical Imaging Conference (IEEE NSS/MIC), 29.10.-06.11.2016, Strasbourg, France

Prompt Gamma Imaging of a Pencil Beam with a High Efficiency Compton Camera at a Clinical Proton Therapy Facility

F. Hueso-González; J. Petzoldt; K. E. Römer; S. Schöne; F. Fiedler; C. Golnik; T. Kormoll; G. Pausch; W. Enghardt

Involved research facilities

Related publications

  • Contribution to proceedings
    2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, 31.10.-07.11.2015, San Diego, USA
    DOI: 10.1109/NSSMIC.2015.7582136

2015

Reichweiteverifikation bei der Protonentherapie mit einer Prompt-Gamma-Schlitzkamera – Auf dem Weg zur klinischen Anwendung

M. Priegnitz; S. Barczyk; C. Golnik; G. Janssens; J. Smeets; F. Vander Stappen; E. Clementel; L. Hotoiu; J. O. de Xivry; M. Baumann; W. Enghardt; F. Fiedler; M. Krause; D. Prieels; G. Pausch; C. Richter

  • Contribution to proceedings
    46. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik, 09.-12.09.2015, Marburg, Deutschland
    DGMP 2015 - 46. Jahrestagung der Deutschen Gesellschaft für Medizinische Physik - Abstractband, 978-3-9816508-8-4, 286-287

2014

First tests of the prompt gamma ray timing method at a clinical proton accelerator

F. Hueso-González; C. Golnik; M. Berthel; A. Dreyer; W. Enghardt; F. Fiedler; G. Janssens; T. Kormoll; J. Petzoldt; D. Prieels; M. Priegnitz; K. E. Römer; J. Smeets; M. Sobiella; F. Vander Stappen; A. Wagner; D. Weinberger; G. Pausch

  • Open Access Logo Contribution to proceedings
    Workshop on Range Assessment and Dose Verification in Particle Therapy, 29.-30.09.2014, Dresden, Germany

Fast Timing with BGO (and other Scintillators) on Digital Silicon Photomultipliers for Prompt Gamma Imaging

J. Petzoldt; K. Roemer; T. Kormoll; M. Berthel; A. Dreyer; W. Enghardt; F. Fiedler; F. Hueso-Gonzalez; C. Golnik; T. Kirschke; A. Wagner; G. Pausch

Involved research facilities

Related publications

  • Contribution to proceedings
    2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (2014 NSS/MIC), 08.-15.11.2014, Seattle, USA
    Proceedings of 2014 NSS/MIC

Particle Range Retrieval in Heterogeneous Phantoms with the Prompt Gamma Timing Method at a Clinical Proton Accelerator

F. Hueso-Gonzalez; C. Golnik; M. Berthel; A. Dreyer; W. Enghardt; F. Fiedler; K. Heidel; G. Janssens; T. Kormoll; J. Petzoldt; D. Prieels; M. Priegnitz; K. E. Roemer; J. Smeets; M. Sobiella; F. Vander Stappen; A. Wagner; D. Weinberger; G. Pausch

Involved research facilities

Related publications

  • Contribution to proceedings
    2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (2014 NSS/MIC), 08.-15.11.2014, Seattle, USA
    Proceedings of 2014 NSS/MIC

Scintillator Characterization at Energies Relevant for a Prompt Gamma Detection System in Particle Therapy

K. Römer; G. Pausch; M. Berthel; A. Dreyer; W. Enghardt; C. Golnik; F. Hueso-González; T. Kormoll; J. Petzoldt; F. Fiedler

Involved research facilities

Related publications

  • Contribution to proceedings
    2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (2014 NSS/MIC), 08.-15.11.2014, Seattle, USA
    Proceedings of 2014 NSS/MIC

Model for the Design of a Prompt Gamma Detection System Using Large Scintillators and Digital Silicon Photomultipliers

K. Römer; G. Pausch; H. Rohling; S. Schöne; W. Enghardt; C. Golnik; F. Hueso-González; T. Kormoll; J. Petzoldt; F. Fiedler

  • Contribution to proceedings
    2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (2014 NSS/MIC), 08.-15.11.2014, Seattle, USA
    Proceedings of 2014 NSS/MIC

2011

A Common Approach to Image Reconstruction for Different Applications of Compton Cameras

S. Schöne; G. Shakirin; T. Kormoll; C.-M. Herbach; G. Pausch; W. Enghardt

  • Contribution to proceedings
    2010 Nuclear Science Symposium and Medical Imaging Conference, 30.10.-06.11.2010, Knoxville TN, USA
    Conference Record 2010 Nuclear Science Symposium and Medical Imaging Conference

Theses

PhD theses

  • Felicia Fibiani Permatasari, Development of a clinically applicable technique for range verification in proton therapy based on the prompt gamma-ray timing (PGT) method, PhD thesis, TUD Dresden University of Technology (2023)
  • Theresa Werner, Reichweiteverifizierung an einem klinischen Protonenstrahl mittels Prompt Gamma-ray Timing Methode: eine Sensitivitätsanalyse, PhD thesis, TUD Dresden University of Technology (2020)
  • David Weinberger, Detektionsmethoden für Gammastrahlung in der therapeutischen Medizin mit CdZnTe-Detektoren, PhD thesis, TUD Dresden University of Technology (2018)
  • Johannes Petzold, Toward the Clinical Application of the Prompt Gamma-Ray Timing Method for Range Verification in Proton Therapy, PhD thesis, TUD Dresden University of Technology (2017)
  • Fernando Hueso Gonzales, Nuclear methods for real-time range verification in proton therapy based on prompt gamma-ray imaging, PhD thesis, TUD Dresden University of Technology (2016)
  • Christian Golnik, Treatment verification in proton therapy based on the detection of prompt gamma-rays, PhD thesis, TUD Dresden University of Technology (2016)
  • Heide Rohling, Simulation studies for the in-vivo dose verification of particle therapy, PhD thesis, TUD Dresden University of Technology (2014)
  • Thomas Kormoll, A Compton Camera for In-vivo Dosimetry in Ion-beam Radiotherapy, PhD thesis, TUD Dresden University of Technology (2013)

Master theses

  • Konstantin Urban, Implementierung und Validierung eines Monte-Carlo-Teilchentransport-Modells für das Prompt Gamma-Ray Timing-System, TUD Dresden University of Technology (2023)
  • Theresa Schröter, Analyse von Energie-Zeit-Verteilungen prompter Gammastrahlung für die Behandlungsverifikation in der Protonentherapie, TUD Dresden University of Technology (2022)
  • Milena Simic, Modeling of an experimental setup for range verification in proton therapy utilizing the prompt gamma ray timing method, University of Niš (2022)
  • Rahel-Debora Werner, Charakterisierung eines schnellen Diamantdetektors als Protonen-Bunch-Monitor für die Reichweiteverifikation in der Protonentherapie, Martin Luther University Halle-Wittenberg (2021)
  • Julia Wiedkamp, Statistische Modellierung der Verifikation der Protonentherapie mittels Prompt Gamma Ray Timing, TUD Dresden University of Technology (2022)
  • Max Küchler (IKTP), Entwicklung einer Methode zur Bestimmung der lokalen Energiedepositionen in der Protonentherapie durch Prompt-Gamma-Signale, TUD Dresden University of Technology (2019)
  • Dominik Kornek, Anwendung von Maximum-Likelihood-Expectation-Maximation und Origin Ensemble zur Rekonstruktion von Aktivitätsverteilungen beim Single Plane Compton Imaging (SPCI), TUD Dresden University of Technology (2019)
  • Maximilian Schmidt, Monitoring der Protonenstrahlzeitstruktur in der Partikeltherapie unter Nutzung gestreuter Protonen, TUD Dresden University of Technology (2019)
  • Felix Buch, Messung des Emissionsspektrums prompter Photonen bei der Bestrahlung homogener Targets mit Protonen, TUD Dresden University of Technology (2018)
  • Jonathan Berthold, Konzeptioneller Test einer Single Plane Compton Camera für die Reichweitemessung in der Protonentherapie, TUD Dresden University of Technology (2017)
  • Nadja Kohlhase, Charakterisierung eines Proton Bunch Monitors hinsichtlich der Prompt Gamma-Ray Timing Methode, TUD Dresden University of Technology (2017)
  • Clara Müller, Untersuchung des Verhaltens eines Detektorsystems unter Lastwechseln im Hinblick auf die Prompt Gamma-Ray Timing Methode, TUD Dresden University of Technology (2017)
  • Andreas Rinscheid, Steps towards the clinical implementation of a digital spectrometer system for range verification in proton therapy, Martin Luther University Halle-Wittenberg (2016)
  • Theresa Werner, Studies of a Proton Bunch Monitor for Range Verification in Proton Therapy, TUD Dresden University of Technology (2015)
  • Alexander Schulz, Untersuchung eines alternativen Konzepts der nuklearmedizinischen Bildgebung mittels kollimatorfreier Detektionssysteme, TUD Dresden University of Technology (2015)
  • Frauke Beyer, Untersuchung eines neuen Konzepts für eine Bildgebung anhand der richtungsauflösenden Gammadetektion, TUD Dresden University of Technology (2014)

Bachelor theses

  • Jessica Tiebel, Charakterisierung des Phasenmonitors Uφ als Protonen-Bunch-Monitor zur Behandlungsverifikation in der Protonentherapie, TUD Dresden University of Technology (2022)
  • Anna Franke, Einsatz eines Diamantdetektors als Proton Bunch Monitor in der Protonentherapie, TUD Dresden University of Technology (2022)
  • Florian Rost, Bestimmung und Optimierung der Ortsauflösung eines granularen Szintillationsdetektors mit einem pixelierten Silizium-Photomultiplier-Sensor für Anwendungen im Single-Plane Compton-Imaging (SPCI) für die Protonenstrahl-Tumortherapie und in der Winkelkorrelationsmessung von Annihilationsphotonen, TUD Dresden University of Technology (2019)
  • Max Küchler, Einfluss starker Lastwechsel auf die Zeitnahme von Szintillationsdetektoren, TUD Dresden University of Technology (2018)
  • Jonathan Berthold, Analyse von Pencil Beam Bestrahlungen für die Reichweitenkontrolle in der Protonentherapie mittels Prompt Gamma Timing, TUD Dresden University of Technology (2015)
  • Paul Jannusch, Untersuchung eines alternativen Konzepts zur bildgebenden Messung von Gammastrahlung in der Nuklearmedizin, TUD Dresden University of Technology (2014)

Invited Talks

2019

Single Plane Compton Imaging for Radionuclide and Prompt Gamma-Ray Imaging

T. Kögler; J. Berthold; B. Deneva; W. Enghardt; K. Römer; A. Straessner; A. Wagner; T. Werner; G. Pausch

  • Invited lecture (Conferences)
    International Conference on Nuclear Data for Science and Technology 2019, 19.-24.05.2019, Beijing, China

2017

Range verification in proton therapy and related activities at OncoRay

G. Pausch

Involved research facilities

Related publications

  • Invited lecture (Conferences)
    Annual Meeting of the Gilbert H. Fletcher Society, 21.-22.06.2017, Dresden, Germany

In-vivo Dosimetrie in der Partikeltherapie – eine Herausforderung für die öffentliche und industrielle Forschung

G. Pausch

Involved research facilities

Related publications

  • Invited lecture (Conferences)
    Jahrestagung der Deutschen Physikalischen Gesellschaft (DPG), AIW Industrietag, 30.03.2017, Münster, Deutschland

2014

System Integration and Application of CdZnTe Detectors in a Compton Camera for Medical Use

F. Fiedler; W. Enghardt; C. Golnik; F. Hueso-Gonzalez; T. Kormoll; A. Schumann; G. Pausch; J. Petzold; H. Rohling; K. Roemer; S. Schoene

  • Invited lecture (Conferences)
    IEEE NSS MIC, 21st Symposium on room-temperature Semiconductor and Gamma-Ray detectors, 08.-15.11.2014, Seattle, WA, USA

Patents

2015

P1324 - Verfahren und Einrichtung zur Kontrolle der Reichweite von Partikelstrahlung einer Bestrahlungseinrichtung zur Strahlentherapie

W. Enghardt; C. Golnik; G. Pausch; F. Hueso-Gonzalez

  • Patent
    DE102013218982 - Offenlegung 26.03.2015, Nachanmeldung: WO, US, EP, JP