Post Test Calculations to 11% Break LOCA Experiments at the Integral Test Facility ISB-VVER Using the Thermohydraulic Code ATHLET


Post Test Calculations to 11% Break LOCA Experiments at the Integral Test Facility ISB-VVER Using the Thermohydraulic Code ATHLET

Krepper, E.

The considered test was a break on the upper plenum with different modes of emergency core cooling. The reference case was the non-availability of emergency cooling. Injecting the emergency coolant into the cold leg, no increasing of rod cladding temperatures was observed, but natural circulation instabilities occurred. Injecting the cooling into the hot leg, the cooling situation was getting worse. Due to the injected cold emergency coolant, the fluid density in the discharge volume was enhanced and the break mass flow increased. The observed events in the test were reproduced by the code with good agreement

Permalink: https://www.hzdr.de/publications/Publ-1112