Pulsed Mode Operation and Longitudinal Parameter Measurement of the Rossendorf SRF Gun


Pulsed Mode Operation and Longitudinal Parameter Measurement of the Rossendorf SRF Gun

Teichert, J.; Arnold, A.; Buettig, H.; Justus, M.; Lehnert, U.; Michel, P.; Schamlott, A.; Schneider, C.; Schurig, R.; Xiang, R.; Klemz, G.; Kamps, T.; Rudolph, J.; Schenk, M.; Will, I.

The Rossendorf SRF gun with a 3 1/2 cell cavity has been operated since 2007. It has produced CW beam with the electron energy of 3 MeV and the average current up to 16 μA. The electron beam of the gun has successfully injected the ELBE superconducting linac since 2010. The Nb cavity has shown constant quality during the operation and for the Cs2Te photocathode life time of months could be obtained. Recently the gun started to run in the pulsed mode with higher gradient. The longitudinal parameters have been measured in this mode. The dark current arose from the high gradient is studied. The main field emission source has been found to be the half cell. Meanwhile, two modified 3+1/2 cell niobium cavities have been fabricated and tested in Jlab. In this paper the new status of the SRF gun will be presented, and the latest results of the beam experiments will be discussed.

Involved research facilities

Related publications

  • Poster
    IPAC 2011, 04.-09.09.2011, San Sebastian, Spain
  • Open Access Logo Contribution to proceedings
    IPAC 2011, 04.-09.09.2011, San Sebastian, Spain
    Proceedings of IPAC2011, 262-264

Downloads

Permalink: https://www.hzdr.de/publications/Publ-15718