Tests of Silicon Photomultipliers for NeuLAND
Tests of Silicon Photomultipliers for NeuLAND
Reinhardt, T.; Bemmerer, D.; Cowan, T.; Heidel, K.; Kempe, M.; Röder, M.; Stach, D.; Wagner, A.; Zuber, K.
NeuLAND, the successor of the LAND time-of-flight neutron spectrometer is planned to be constructed of 5 × 5 × 250 cm3 scintillator bars of RP-408 [1] or equivalent. Light readout will be performed by 1" photomultiplier tubes (PMTs). A demonstration prototype of the detector concept was recently tested at GSI [2]. During the operation of the complete detector with 6,000 channels a significant number of photomultiplier tubes may have to be replaced each year. Recent developments in the field of semiconductor based photon readout systems [2, e.g.] raise the possibility of using Silicon Photomultipliers (SiPMs) for this task.
Related publications
- DOI: 10.17815/jlsrf-2-58 is cited by this (Id 22008) publication
-
Contribution to external collection
Katrin Große: GSI Scientific Report 2012, GSI Report 2013-1, Darmstadt: GSI Helmholtzzentrum für Schwerionenforschung, 2013
Downloads
Permalink: https://www.hzdr.de/publications/Publ-22008