Dataset for: Morphology of flashing feeds at critical fluid properties in larger pipes


Dataset for: Morphology of flashing feeds at critical fluid properties in larger pipes

Döß, A.; Schubert, M.; Hampel, U.
DataManager: Wiezorek, Michael

This data set contains cross-sectional averaged vapor fraction data obtained for flashing refrigerant in the horizontal feed section (inner pipe diameter of 200 mm) of the TERESA facility. The data was obtained with the Wire-mesh Sensor Framework GUI (Version 1.3.0). The archive 'void' contains .epst-files which are organized as a two column table (ASCII). The first column denotes the time step (in seconds), the second column is the cross-sectional averaged vapor fraction in percent.

Allocation of the files to the operational conditions is included separate .csv-file (overview.csv), which contains 12 columns for each measurement. Here the averaged values of the .epst-files are included as well.

In this study, two wire-mesh sensors were operated simultaneously. WMS1 (*_X_Sensor_1.epst) was located in an axial distance of L = 2.5 D from the flash nozzle and WMS2 (*_Y_Sensor_2.epst) was located L = 17.5 D away from the flash nozzle.  

Keywords: TERESA; Flashing feed; Wire-mesh sensor