Upgrade of the ELBE Timing System


Upgrade of the ELBE Timing System

Kuntzsch, M.; Schwarz, A.; Zenker, K.; Justus, M.; Oven, Z.; Krmpotic, L.; Legat, U.; Rojec, U.

At the ELBE accelerator center a superconducting linac is operated to drive manifold secondary radiation sources like two infrared FELs, a positron source and a THz facility. The machine uses two injectors as electron sources that are accelerated in the main linac. The user experiments demand a large variety of bunch patterns from single shot to macro pulsed and cw beam at up to 26 MHz repetition rate. At ELBE a new timing system is being developed based on the MRF hardware platform and the MRF Timing System IOC. It uses two masters and a scalable number of connected receivers to generate the desired pulse patterns for operating the machine and to control user experiments. The contribution will show the architecture of the timing system, the control interfacing and performance measurements acquired on the test bench.

Keywords: ELBE; Timing; MicroTCA

Related publications

  • Contribution to proceedings
    International Particle Accelerator Conference 2021, 24.-28.05.2021, Campinas, Brazil
    Upgrade of the ELBE Timing System
  • Poster (Online presentation)
    International Particle Accelerator Conference 2021, 24.-28.05.2021, Campina, Brazil

Permalink: https://www.hzdr.de/publications/Publ-32917
Publ.-Id: 32917