A semi-analytical model for the description of coolant mixing inside the KONVOI reactor pressure vessel during pump start-up
A semi-analytical model for the description of coolant mixing inside the KONVOI reactor pressure vessel during pump start-up
Kliem, S.; Prasser, H.-M.
The coolant mixing in the downcomer and the lower plenum during pump start-up has been investigated experimentally at the ROCOM test facility. This facility is a 1:5 linearly scaled model of the KONVOI reactor pressure vessel. Transfer functions for a semi-analytical model have been derived from these experiments. The comparison of the model with further experiments and a computational fluid dynamics calculation is presented.
Keywords: Coolant mixing; pump start-up
-
Lecture (Conference)
Jahrestagung Kerntechnik 2001, Dresden, 15.-17. Mai 2001, Tagungsbericht, S. 107-112 -
Contribution to proceedings
Jahrestagung Kerntechnik 2001, Dresden, 15.-17. Mai 2001, Tagungsbericht, S. 107-112
Permalink: https://www.hzdr.de/publications/Publ-3625
Publ.-Id: 3625