Laboratory -unit investigations of palladium treated titanium foil for dry scrubber application


Laboratory -unit investigations of palladium treated titanium foil for dry scrubber application

Piekoszewski, J.; Chmielewski, A. G.; Licki, J.; Sartowska, B.; Werner, Z.; Barson, S. D.; Skeldon, P.; Thompson, G. E.; Richter, E.; Wieser, E.

Titanium foil is employed for electron transparent windows in the electron beam dry scrubber process. The foil suffers corrosion, which limits the window life. Here, the examination of palladium-coated window, prepared by ion beam assisted deposition and plasma source ion assisted deposition (PSIAD), after service in a pilot-scale plant is reported. Most significantly, the adhesion of the coating was reduced by the flue gas. Where the coating remained adherent, corrosion was negligible. Elswhere, generalmintergranular and pitting corrosin occured. A PSIAD coating provided the best performance.

Keywords: Electron beam treatment; Flue gases; Ttanium; Palladiumn; Corrosion; Coatings

  • Radiation Physics and Chemistry 62 (2001) 253-260

Permalink: https://www.hzdr.de/publications/Publ-4621