Implementation of temperature control into a high resolution gamma ray detector for tomography applications
Implementation of temperature control into a high resolution gamma ray detector for tomography applications
Bieberle, A.; Bärtling, Y.; Fleischer, A.; Sühnel, T.; Zimmermann, W.; Schleicher, E.; Hampel, U.
In this paper the development of a new thermal design for a high resolution gamma ray computed tomography detector is presented. The new design has become necessary due to stringent requirements on count rate accuracy under varying thermal conditions at thermal hydraulic test loops. The components of the existing tomography detector have been analysed with respect to their thermal response and a new arrangement has been devised that is optimized with respect to efficient heat conduction from internal as well as external heat sources to a cooling circuit.
Keywords: gamma ray tomography; temperature control
-
Contribution to proceedings
5th International Symposium on Process Tomography, 25.-26.08.08, Zakopane, Poland
PaperNo PT08_cr12 -
Poster
5th International Symposium on Process Tomography, 25.-26.08.08, Zakopane, Polen
Permalink: https://www.hzdr.de/publications/Publ-11183