Recent progress in ultra fast electron beam X-ray computed tomography


Recent progress in ultra fast electron beam X-ray computed tomography

Hampel, U.; Fischer, F.; Bieberle, M.; Schleicher, E.

A new ultra fast electron beam X-ray CT scanner has been developed, implemented and tested in different applications. It consists, amongst other components, of an electron beam unit with 10 kHz scanning capability and 1 mm focal spot size and a 240 element circular CZT detector arc. The system is capable to produce slice images at up to 7 kHz frame rate of moderately absorbing objects with maximum 120 mm diameter. The paper introduces the scanner and first results for two-phase flow measurements in a bubble column and a fluidized bed.

Keywords: ultra fast electron beam ray tomography; two-phase flow

  • Contribution to proceedings
    5th International Symposium on Process Tomography, 25.-26.08.2008, Zakopane, Poland
    Proceedings of the 5th International Symposium on Process Tomography, Paper No. PT08_cr11
  • Lecture (Conference)
    5th International Symposium on Process Tomography, 25.-26.08.2008, Zakopane, Poland

Permalink: https://www.hzdr.de/publications/Publ-11232