Flow imaging by high speed transmission tomography


Flow imaging by high speed transmission tomography

Johansen, G. A.; Hampel, U.; Hjertaker, B. T.

Fourth generation medical x-ray scanners using a gantry with a rotating X-ray source and a fixed circular detector array as sensor head, are too slow for imaging of the process dynamics for instance in multiphase flows. To avoid inconsistent measurements and motion blurring, all measurements need to be carried out in a short time compared to the process time constants of the process dynamics. Two different high speed tomographic imaging systems are presented here demonstrating that image rates of several thousand images per second is possible.

Keywords: High speed tomographic imaging; Gamma-ray tomography; X-ray tomography; Electron beam scanning tomography; Flow imaging