Rossendorf SRF-Gun Cavity Characteristics


Rossendorf SRF-Gun Cavity Characteristics

Arnold, A.; Teichert, J.; Buettig, H.; Janssen, D.; Justus, M.; Lehnert, U.; Michel, P.; Murcek, P.; Schamlott, A.; Schneider, C.; Schurig, R.; Staufenbiel, F.; Wiang, R.; Kamps, T.; Rudolph, J.; Schenk, M.; Klemz, G.; Will, I.

At the Forschungszentrum Rossendorf the development and the setup of the 2nd superconducting radio frequency photo electron injector (SRF-Photo-Gun) is finished. This new injector is placed next to the existing thermionic gun of the superconducting linear accelerator called ELBE. In the next shutdown a connection between this accelerator and the SRF-Gun will provide the improved beam parameters for the users. At the moment the commissioning is fully under way.
The contribution will present important results concerning cavity commissioning like measurements of: Q vs. E, microphonics, Lorentz detuning, tuner parameters, spectra HOM excitation spectra and the field distribution calculated from measured fundamental mode passband. The results will be used to improve the existing cavity design.

Involved research facilities

Related publications

  • Poster
    Workshop on Sources of Polarized Electrons and High Brightness Electron Beams, 01.-03.10.2008, Newport News, USA
  • Contribution to proceedings
    SPIN PHYSICS: 18th International Spin Physics Symposium, 06.-11.11.2008, Charlottesville, Virginia, USA
    AIP Conference Proceedings, Volume 1149,, Melville/NY, 978-0-7354-0686-5, 1125-1132
  • Poster
    First DITANET School on Beam Diagnostics, 30.03.-03.04.2009, London, UK

Downloads

Permalink: https://www.hzdr.de/publications/Publ-12390