Status of the Penning trap project in Munich
Status of the Penning trap project in Munich
Szerypo, J.; Kolhinen, V.; Bussmann, M.; Gartzke, E.; Habs, D.; Neumayr, J.; Schramm, U.; Schürmann, C.; Sewtz, M.; Thirolf, P.
The MLLTRAP at the Maier-Leibnitz-Laboratory (Garching) is a new Penning trap facility designed to combine several novel technologies to decelerate, charge breed, cool, bunch and purify the reaction products and perform high-accuracy nuclear and atomic mass measurements. It is now in the commissioning phase, achieving a mass-resolving power of about 105 in the purification trap for stable ions.
Keywords: penning trap; cooling; purification; mass spectrometry; highly charged ions
-
European Physical Journal A 42(2009)3, 319-322
DOI: 10.1140/epja/i2009-10788-3
ISSN: 1434-6001
Permalink: https://www.hzdr.de/publications/Publ-12944