Modelling of Condensation in Horizontal Tubes


Modelling of Condensation in Horizontal Tubes

Schaffrath, A.; Krüssenberg, A.-K.; Fjodorow, A.; Gocht, U.; Lischke, W.

The condensation in horizontal tubes plays an important role e.g. for the determination of the operation mode of horizontal steam generators of VVER reactors or passive safety systems for the next generation of nuclear power plants. Two different approaches (HOTKON and KONWAR) for modeling this process have been undertaken by Forschungszentrum Jülich (FZJ) and University for Applied Sciences Zittau/Görlitz (HTWS) and implemented into the 1D-thermohydraulic code ATHLET, which is developed by the Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbH for the analysis of anticipated and abnormal transients in light water reactors.
Although the improvements of the condensation models are developed for different applications (VVER steam generators - emergency condenser of the SWR1000) with strongly different operation conditions (e.g. the temperature difference over the tube wall in HORUS is up to 30 K and in NOKO up to 250 K, the heat flux density in HORUS is up to 40 kW/m² and in NOKO up to 1 GW/m²) both models are now compared and assessed by Forschungszentrum Rossendorf FZR e.V. Therefore post test calculations of four selected HORUS experiments were performed with ATHLET/KONWAR. It can be seen that the calculations with the extension KONWAR as well as HOTKON improve significantly the agreement between computational and experimental data.

Keywords: condensation inside horizontal tubes; ATHLET; HORUS; HOTKON; KONWAR

  • Lecture (Conference)
    Ninth International Topical Meeting on Nuclear Hydraulics (NURETH-9), San Francisco, California, 5th Oct 1999, CD-ROM
  • Contribution to proceedings
    Ninth International Topical Meeting on Nuclear Hydraulics (NURETH-9), San Francisco, California, 5th Oct 1999, CD-ROM

Permalink: https://www.hzdr.de/publications/Publ-1421