Strip Readout RPC Based on Low Resistivity Glass Electrodes


Strip Readout RPC Based on Low Resistivity Glass Electrodes

Petris, M.; Petrovici, M.; Simion, V.; Bartos, D.; Caragheorgheopol, G.; Dohrmann, F.; Hildenbrand, K. D.; Kämpfer, B.; Kotte, R.; Naumann, L.; Stach, D.; Williams, M. C. S.; Wüstenfeld, J.

We present the prototype of a Resistive Plate Counter equipped with electrodes made from Pestov Glass (~ 1010 Ω cm). It is aimed as solution for TOF subdetector of CBM experiment at the future FAIR facility in Darmstadt. Details of the design and the construction are introduced. Results of tests with radioactive sources and of in-beam investigations on time resolution and counting rate capability are discussed.

Involved research facilities

Related publications

  • Open Access Logo Romanian Journal of Physics 56(2011), 349-358

Permalink: https://www.hzdr.de/publications/Publ-15764