Correlation for Countercurrent Flow Limitation in a PWR Hot Leg


Correlation for Countercurrent Flow Limitation in a PWR Hot Leg

Murase, M.; Tomiyama, A.; Lucas, D.; Kinoshita, I.; Utanohara, Y.; Yanagi, C.

Numerical simulations have been done to evaluate CCFL (countercurrent flow limitation) in a PWR hot leg under reflux condensation by using a VOF (volume of fluid) method implemented in the CFD software, FLUENT6.3.26. The calculated CCFL characteristics have been verified and agreed well with known values including the UPTF data at 1.5 MPa. Therefore, in this paper, parameter calculations using the VOF method were done for system pressures up to 8 MPa under PWR full-scale conditions with the diameter of 750 mm. As a result, calculated CCFL characteristics in the Wallis diagram were slightly mitigated from 0.1 MPa to 1.5 MPa with increasing system pressure, but they did not change from 1.5 MPa to 8 MPa. The CCFL database calculated in this study and values measured under air-water and steam-water conditions were used to derive a CCFL correlation and its uncertainty, where the CCFL constant was . Most of the CCFL data and the current correlation predictions were within the uncertainty of +-0.03.

Keywords: reflux condensation; PWR hot leg; countercurrent gas-liquid flow; CCFL; numerical simulation