Experimental Investigations on Vertical Pipe Flow Using Ultrafast Electron-Beam X-Ray Tomography
Experimental Investigations on Vertical Pipe Flow Using Ultrafast Electron-Beam X-Ray Tomography
Banowski, M.; Lucas, D.; Hoppe, D.; Barthel, F.; Szalinski, L.; Sprewitz, U.; Beyer, M.; Hampel, U.
This presentation introduces into the tomography measurement system and the vertical pipe test facility for liquid-gas experiments at TOPFLOW. The reconstruction and data evaluation algorithms are discussed shortly. Some results of two-phase upward flow experimental series for air-water and steam-water flow regimes are showed with qualitative and quantitative data. Finally limits and errors of this measurement technique are presented.
Keywords: two-phase; measuring technique; X-ray; tomography; pipe flow; bubble
Involved research facilities
- TOPFLOW Facility
-
Lecture (Conference)
10th Multiphase Flow Conference: Simulation, Experiment and Application, 13.-14.06.2012, Dresden, Deutschland -
Contribution to proceedings
10th Multiphase Flow Conference: Simulation, Experiment and Application, 13.-14.06.2012, Dresden, Deutschland
CD-ROM
Permalink: https://www.hzdr.de/publications/Publ-17659