Post Test Calculations to 11% Break LOCA Experiments in the Integral Test Facility ISB-VVER Using the Thermalhydraulic Code ATHLET
Post Test Calculations to 11% Break LOCA Experiments in the Integral Test Facility ISB-VVER Using the Thermalhydraulic Code ATHLET
Krepper, E.
The considered test was a break on the upper plenum with different modes of emergency core cooling. The reference case was the non-availability of emergency cooling. Injecting the emergency coolant into the cold leg, no increasing of rod cladding temperatures was observed, but natural circulation instabilities occurred. Injecting the cooling into the hot leg, the cooling situation was getting worse. Due to the injected cold emergency coolant, the fluid density in the discharge volume was enhanced and the break mass flow increased. The observed events in the test were reproduced by the code with good agreement
-
Contribution to proceedings
Proc. Jahrestagung Kerntechnik, Nürnberg, 16. - 18. Mai 1995, pp. 83 - 87 -
Contribution to proceedings
Conference "Thermopysical Aspects of WWER-Type Reactor Safety", Obninsk, Russia, Nov. 1995, Proc. Vol. 2, pp. 150 - 154
Permalink: https://www.hzdr.de/publications/Publ-1777