Contactless inductive flow tomography: A liquid metal flow measuring technique complementary to UDV
Contactless inductive flow tomography: A liquid metal flow measuring technique complementary to UDV
Stefani, F.; Gerbeth, G.; Gundrum, T.; Wondrak, T.
The aim of the Contactless Inductive Flow Tomography (CIFT) is the reconstruction of flow structures in metal and semiconductor melts. It relies on the induction of electric currents in moving conductors exposed to magnetic fields. The flow induced deformations of various applied magnetic fields can be measured in the exterior of the melt and utilized for the reconstruction of the velocity field. After a presentation of the principles of CIFT, first applications and possible extensions of the method are discussed and put into the context with traditional measuring techniques such as UDV.
-
Invited lecture (Conferences)
8th International Symposium on Ultrasonic Doppler Methods for Fluid Mechanics and Fluid Engineering, 19.-21.09.2012, Dresden, Germany -
Contribution to proceedings
8th International Symposium on Ultrasonic Doppler Methods for Fluid Mechanics and Fluid Engineering, 19.-21.09.2012, Dresden, Germany
Proceedings of the 8th International Symposium on Ultrasonic Doppler Methods for Fluid Mechanics and Fluid Engineering, Dresden: HZDR, 101-104
Permalink: https://www.hzdr.de/publications/Publ-17964