High-temperature oxidation resistance in yttrium implanted stainless steel
High-temperature oxidation resistance in yttrium implanted stainless steel
Barlak, M.; Piekoszewski, J.; Werner, Z.; Sartowska, B.; Waliś, L.; Starosta, W.; Kierzek, J.; Kowalska, E.; Wilhelm, R. A.; Pochrybniak, C.; Woźnica, M.
Austenitic AISI 304, 316L and ferritic 430 stainless steels were implanted with yttrium to fluences ranging between 1 × 10^15 and 5 × 10^17 ions/cm2. The samples were subjected to oxidation in air at a temperature of 1000°C for a period of 100 h and next examined by stereoscopic optical microscopy (OM), scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDX) and Rutherford back scattering spectrometry (RBS). The results obtained with the use of ion implantation are discussed.
Keywords: high-temperature oxidation resistance; ion implantation; yttrium
Involved research facilities
- Ion Beam Center DOI: 10.17815/jlsrf-3-159
Related publications
- DOI: 10.17815/jlsrf-3-159 is cited by this (Id 17989) publication
-
Nukleonika 57(2012), 473-476
ISSN: 0029-5922
Permalink: https://www.hzdr.de/publications/Publ-17989