Contactless inductive flow tomography and mutual inductance tomography for a model of continuous casting


Contactless inductive flow tomography and mutual inductance tomography for a model of continuous casting

Wondrak, T.; Timmel, K.; Gundrum, T.; Stefani, F.; Eckert, S.; Gerbeth, G.; Peyton, A. J.; Yin, W.; Terzija, N.

We present the results of simultaneous measurements of the flow field in a slab casting mould by the Contactless Inductive Flow Tomography (CIFT) and of the gas/liquid distribution in one cross section of the submerged entry nozzle (SEN) by the Mutual Inductance Tomography (MIT) for a physical model consisting of a mould with the cross section of 140 x 35 mm^2. Additionally, we present a new measuring system for CIFT using pickup coils and the first measurement of the flow field in a mould with the cross section of 400 x 100 mm^2.

Keywords: continuous casting; flow measurement; contactless inductive flow tomography; liquid metal; mutual inductance tomography

  • Open Access Logo Contribution to proceedings
    7th World Congress on Industrial Process Tomography - WCIPT7, 02.-05.09.2013, Krakow, Poland
    Procedia Engineering, 650-659
  • Lecture (Conference)
    7th World Congress on Industrial Process Tomography - WCIPT7, 02.-05.09.2013, Krakow, Poland

Permalink: https://www.hzdr.de/publications/Publ-19897