Evaluation of the cone-shaped pickup performance for low charge sub-10 fs arrival-time measurements at free electron laser facilities


Evaluation of the cone-shaped pickup performance for low charge sub-10 fs arrival-time measurements at free electron laser facilities

Angelovski, A.; Kuntzsch, M.; Czwalinna, M. K.; Penirschke, A.; Hansli, M.; Sydlo, C.; Arsov, V.; Hunziker, S.; Schlarb, H.; Gensch, M.; Schlott, V.; Weiland, T.; Jakoby, R.

An evaluation of the cone-shaped pickup performance as a part of the high bandwidth bunch arrival-time monitors (BAMs) for a low charge sub-10 fs arrival-time measurements is presented. Three sets of pickups are installed at the free electron laser FLASH at Deutsches Elektronen-Synchrotron, the quasi-cw SRF accelerator ELBE at the Helmholtz-Zentrum Dresden-Rossendorf and the SwissFEL injector test facility at Paul Scherrer Institute. Measurements and simulations are in good agreement and the pickups fulfill the design specifications. Utilizing the high bandwidth BAM with the cone-shaped pickups, an improvement of the signal slope by a factor of 10 is demonstrated at ELBE compared to the BAM with a low bandwidth.

Keywords: BAM ELBE FLASH Arrival-Time Diagnostic

Involved research facilities

Related publications

Permalink: https://www.hzdr.de/publications/Publ-21651