Response of Multi-Strip Multi-gap Resistive Plate Chamber


Response of Multi-Strip Multi-gap Resistive Plate Chamber

Datta, U.; Chakraborty, S.; Rahaman, A.; Basu, P.; Basu, J.; Bemmerer, D.; Boretzky, K.; Elekes, Z.; Kempe, M.; Münzenberg, G.; Simon, H.; Sobiella, M.; Stach, D.; Wagner, A.; Yakorev, D.

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm x 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE at Helmholtz-Zentrum Dresden-Rossendorf. In this report the response of SINP developed MMRPC with different controlling parameters is described in details. The obtained time resolution of the detector after slew correction was 91.5 +- 3 ps. Position resolution measured along x and across y the strip was 2.8+-0.6 cm and 0.58 cm, respectively. The measured absolute efficiency of the detector for minimum ionizing particle like electron was 95.8+-1.3 %. Better timing resolution of the detector can be achieved by restricting the events to a single strip. The response of the detector was mainly in avalanche mode but a few percentage of streamer mode response was also observed. A comparison of the response of these two modes with trigger rate was studied.

Keywords: Multi-strip Multi-gap Resistive Plate chamber (MMRPC) ELBE

Involved research facilities

Related publications

Permalink: https://www.hzdr.de/publications/Publ-22146