An improved SRF gun (ELBE SRF gun II) has been installed and commissioned at HZDR. This new gun replaced the first SRF gun of the ELBE accelerator which had been in operation since 2007. The new gun has an improved 3.5-cell niobium cavity those SRF performances have been studied first with a copper cathode. After the replacement by our standard Cs2Tecathode we observed a tremendous degradation of the cavity gradient paired with an increase of field emission. In this contribution we will report on our in-situ investigations to find the origin and the reason for the particle contamination that happened during the first cathode transfer.