Study of Magnesium Photocathodes for Superconducting RF Photoinjectors


Study of Magnesium Photocathodes for Superconducting RF Photoinjectors

Xiang, R.; Arnold, A.; Lu, P. N.; Murcek, P.; Teichert, J.; Vennekate, H.

The superconducting RF photoinjector (SRF Gun II) has successfully served for the ELBE user facility at HZDR. The quality of photocathodes is one of the most critical issues in improving the stability and reliability for its application. Mg has a comparably low work function and shows quantum efficiency up to 0.3% after laser cleaning. But the present cleaning with a high intensity laser beam is time consuming and produces unwanted surface roughness. Thermal treatment and excimer laser cleaning are being investigated as alternative methods.

Keywords: electron source; photocathode; Mg; SRF gun; superconducting RF; laser cleaning

Involved research facilities

Related publications

  • Poster
    9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada
  • Open Access Logo Contribution to proceedings
    9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada
    Proceedings of the 9th International Particle Accelerator Conference IPAC´18, Genf: JACoW, 4142-4144
    DOI: 10.18429/JACoW-IPAC2018-THPMF039

Permalink: https://www.hzdr.de/publications/Publ-27494