Experiences with the SRF Gun II for User Operation at the ELBE Radiation Source
Experiences with the SRF Gun II for User Operation at the ELBE Radiation Source
Teichert, J.; Arnold, A.; Bawatna, M.; Evtushenko, P. E.; Gensch, M.; Green, B. W.; Kovalev, S.; Lehnert, U.; Lu, P. N.; Michel, P.; Murcek, P.; Vennekate, H.; Xiang, R.
The second version of the superconducting RF photoinjector (SRF Gun II) was successfully commissioned at the ELBE radiation source in 2014. The gun features an improved 3.5-cell niobium cavity combined with a superconducting solenoid integrated in the cryostat. With a Mg photocathode the SRF Gun II is able to generate bunches with up to 200 pC and with sub-ps length in CW mode with 100 kHz pulse frequency for the THz radiation facility at ELBE. In the ELBE linac, the beam is accelerated, gets a proper correlated energy spread, and is compressed in a magnetic chicane. Sub-ps pulses are obtained producing coherent diffraction radiation and superradiant undulator radiation.
Keywords: electron source; SRF gun; superconducting RF; THz radiation; coherent diffration radiation; superradiant radiation; ELBE
Involved research facilities
- Radiation Source ELBE DOI: 10.17815/jlsrf-2-58
Related publications
- DOI: 10.17815/jlsrf-2-58 is cited by this (Id 27495) publication
-
Poster
9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada -
Contribution to proceedings
9th International Particle Accelerator Conference IPAC´18, 29.04.-04.05.2018, Vancouver, Canada
Proceedings of the 9th International Particle Accelerator Conference IPAC´18, Genf: JACoW, 1247-1250
DOI: 10.18429/JACoW-IPAC2018-THPMF040
Permalink: https://www.hzdr.de/publications/Publ-27495