On-Chip THz spectrometer for bunch compression fingerprinting at fourth-generation light sources


On-Chip THz spectrometer for bunch compression fingerprinting at fourth-generation light sources

Laabs, M.; Neumann, N.; Green, B.; Awari, N.; Deinert, J.; Kovalev, S.; Plettemeier, D.; Gensch, M.

In this letter we present the layout and demonstrate the performance for an integrated millimeter-scale on-chip THz spectrometer. The device is based on eight Schottky-Diode detectors which are combined with narrow-band THz antennas, thereby enabling the simultaneous detection of eight frequencies in the THz range on one chip. The size of the active detector area matches the focal spot size of superradiant THz radiation utilized in bunch compression monitors of modern linear electron accelerators. The 3 dB bandwidth of the on-chip Schottky-Diode detectors is less than 10% of the center frequency and allows pulse-resolved detection at up to 5 GHz repetition rates. The performance of a first prototype device is demonstrated at a repetition rate of 100 kHz at the quasi-cw SRF linear accelerator ELBE operated with electron bunch charges between few pC and 100 pC.

Involved research facilities

Related publications

Permalink: https://www.hzdr.de/publications/Publ-27797