Modelling of multidimensional effects in thermal-hydraulic system codes under asymmetric flow conditions – Simulation of ROCOM Tests 1.1 and 2.1 with ATHLET 3D-Module


Modelling of multidimensional effects in thermal-hydraulic system codes under asymmetric flow conditions – Simulation of ROCOM Tests 1.1 and 2.1 with ATHLET 3D-Module

Diaz Pescador, E.; Schäfer, F.; Kliem, S.

Abstract

The implementation and validation of multidimensional (multi-D) features in thermal-hydraulic system codes aims to extend the application of these codes towards multi-scale simulations. The main goal is the simulation of large-scale three-dimensional effects inside large volumes such as piping or vessel. This novel approach becomes especially relevant during the simulation of accidents with strongly asymmetric flow conditions entailing density gradients. Under such conditions, coolant mixing is a key phenomenon on the eventual variation of the coolant temperature and/or boron concentration at the core inlet and on the extent of a local re-criticality based on the reactivity feedback effects. This approach presents several advantages compared to CFD calculations, mainly concerning the model size and computational effort. However, the range of applicability and accuracy of the newly implemented physical models at this point is still limited and needs to be further extended. This paper aims at contributing to the validation of the multi-D features of the system code ATHLET based on the simulation of the Tests 1.1 and 2.1, conducted at the test facility ROCOM. Overall, the multi-D features of ATHLET predict reasonably well the results from both experiments, although discrepancies are observed at the core inlet concerning the coolant temperature distribution.

Keywords: ATHLET; Coolant mixing; Overcooling transient; ROCOM; Test 1.1 & 2.1

Permalink: https://www.hzdr.de/publications/Publ-29123