Capacity and sizing of wire mesh mist eliminators at critical fluid properties


Capacity and sizing of wire mesh mist eliminators at critical fluid properties

Flegiel, F.; Windmeier, C.; Wiezorek, M.; Döß, A.; Schubert, M.; Hampel, U.; Schleicher, E.

Wire mesh flooding point measurements at low surface tension < 10 mN m-1 were conducted using a refrigerant as model fluid. A new method for the calculation of wire mesh capacity was developed based on experimental data from literature and data from this study. In comparison to the well-known and widely adapted K-value method given in the Gas Processors Suppliers Association (GPSA) Engineering Databook and various other sources, the new method yields 3-38 % reduced wire mesh cross-sections for fluid systems at pressures above 20 bar(g) while retaining an inherent safety margin.

Keywords: flooding point; K-value; wire-mesh; mist eliminator capacity

Involved research facilities

  • TOPFLOW Facility

Permalink: https://www.hzdr.de/publications/Publ-31637