Spectral X-ray computed micro tomography: a tool for 3-dimensional chemical imaging


Spectral X-ray computed micro tomography: a tool for 3-dimensional chemical imaging

Sittner, J.; Merkulova, M.; Da Assuncao Godinho, J. R.; Renno, A.; Cnudde, V.; Boone, M.; de Schryver, T.; van Loo, D.; Roine, A.; Liipo, J.; Dewaele, S.; Guy, B. M.

Image-based analytical tools in geosciences are indispensable for the characterization of minerals, but most of them are limited to the surface of a polished plane in a sample and lack 3D information. X-ray micro computed tomography (micro CT) provides the missing 3D information of the microstructures inside samples. However, a major drawback of micro CT in the characterization of minerals is the lack of chemical information that makes mineral classification challenging.
Spectral X-ray micro computed tomography (Sp-CT) is a new and evolving tool in different applications such as medicine, security, material science, and geology. This non-destructive method uses a multi-pixel photon-counting detector (PCD) such as cadmium telluride (CdTe) in combination with a conventional CT scanner (TESCAN CoreTOM) to image a sample and detect its transmitted polychromatic X-ray spectrum. Based on the spectrum, elements in a sample can be identified by an increase in attenuation at specific K-edge energies. Therefore, chemically different particles can be distinguished inside a sample from a single CT scan. The method is able to distinguish elements with K-edges in the range from 25 to 160 keV, which applies to elements with Z > 48.
We present results from various sample materials. Different pure elements and element oxides were measured to compare the position of theoretical and measured K-edge energies. All measured K-edge energies are slightly above the theoretical value, but based on the results a correction algorithm could be developed. Furthermore, different monazite grains were investigated, which can be divided into two groups with respect to the content of different RE elements on the basis of the spectrum: La-Ce-rich and La-Ce-poor. In addition, samples from the Au-U Witwatersrand Supergroup demonstrate the potential applications of Sp-CT for geological samples. We measured different drill core samples from the Kalkoenkrans Reef at the Welkom Gold field. Sp-CT can distinguish gold, uraninite and galena grains based on their K-edge energies in the drill core without preparation.

  • Lecture (Conference) (Online presentation)
    European Geoscience Union (EGU) 2021, 19.-30.04.2021, Online, Online

Permalink: https://www.hzdr.de/publications/Publ-33595