MetroPOEM – Metrology for the harmonisation of measurements of environmental pollutants in Europe


MetroPOEM – Metrology for the harmonisation of measurements of environmental pollutants in Europe

Arnold, D.; Eberhardt, J.; Flierl, L.; Rienitz, O.; Pramann, A.; Zapata, D.; Vogl, J.; Prem, P. S.; Lourenço, V.; Chambon, L.; Isnard, H.; Mazánová, M.; Sochorová, J.; Zuliani, T.; Goltnik, T.; Rovan, L.; Štrok, M.; Noireaux, J.; Kamarainen, M.; Engin, B. A.; Can, S. Z.; Cankur, O.; İşleyen, A.; Hansen, V.; Ulrich, T.; Andreasen, R.; Hou, X.; Qiao, J.; Pröfrock, D.; Wippermann, D.; Zimmermann, T.; Winkler, S.; Fichter, S.; Wallner, A.; Schöpke, C.; Johansen, I.; Yasin, V.; Ioan, M.-R.; Virgolici, M.; Olaru, C.; Badea, R.; Walther, C.; Irrgeher, J.; Lancaster, S.; Epov, A.; Chernonozhkin, S.; Wagner, S.; Jerome, S.; Skipperud, L.; Jensen, K.-A.; Salminen-Paatero, S.; Vukanac, I.; Čeliković, I.; Rajačić, I.; Djurašević, M.; Nikolić, J. K.; Christl, M.; Tribouillier, H. P.; Malinovskiy, D.; Hil, S.; Goenaga-Infante, H.; Strekopytov, S.; Russell, B.; Mohamud, H.; Thompkins, H.

Summary

The European Green Deal’s ambition for zero pollution requires the development of highly sensitive techniques to detect ultra-low amounts of pollutants. This requirement will be delivered via strategies described by the two European Metrology Network (EMN) on Pollution Monitoring (PolMo) and the EMN on Radiation Protection, supporting the Basic Safety Standards directive. Implicit in these strategies is a strong need to improve data quality for monitoring and reporting pollution in the air, water, and soil. To detect radioactive isotopes and stable polluting elements in the environment, fast, sensitive, and inexpensive analytical procedures are needed. Mass spectrometry is a key method for determination of non-radioactive polluting elements and of increasing importance for long-lived radionuclides, however, application of single collector ICP-MS, this potential cannot be fully realised unless techniques are validated with traceable multi-element reference materials. However, multi-element certified reference materials are usually not available and single-element certified reference materials are limited to very few elements. Nevertheless, these reference materials are urgently needed to calibrate mass spectrometric measurements, to overcome mass bias effects occurring during the measurements in mass spectrometers. The MetroPOEM project (21GRD09) is designed to address these problems. MetroPOEM, coordinated by the Physikalisch-Technische Bundesanstalt of Germany, will be delivered by a consortium of 22 partners from 13 countries throughout Europe.

Objectives

The overall aim of MetroPOEM is to bridge the gap between radiometric techniques and mass spectrometry for the characterisation and detection of polluting long-lived radionuclides and stable elements and element tracers by comparing and linking both techniques, thus significantly improving measurement uncertainties and detection limits. These aims and objectives will be delivered through four technical work packages, supported by project and impact management activities:

  • Establish and compare (inter-laboratory) the selectivity and detection limits of diverse types of mass spectrometers for selected radioactive pollutants (e.g., U, Np, Pu, Am) using isotope reference materials and/or activity standards. This includes assessing relative instrument performance with respect to current measurement challenges and establishing detection limits in relation to environmental regulations.
  • Develop measurement methods for isotope ratios that are traceable to the SI by using multi-collector ICP-MS and apply these methods on more commonly available techniques (ICP-MS/MS, ICP-QMS) by providing suitable operating procedures focussing on stable polluting elements (e.g., Li, B, Cr, Cd, Ni, Sb, Pb, U). To produce recommendations for sample processing, treatment, uncertainty budgets, and if feasible, the quantification of the so-called mass bias.
  • Develop two radioactive reference materials with the sample matrix containing radioactive pollutants (e.g., U, Np, Pu, Am) for use in an inter-laboratory comparison employing techniques used WP1, which will demonstrate the variations in parameters including detection limits, sample preparation, sample introduction methods, total procedural time, and uncertainty budgets.
  • Implement and validate the methods for isotope ratio measurements established in objective 2 by the development of one aqueous certified reference material that is certified for the same stable polluting elements with lowest possible uncertainties using multi-collector instruments, to facilitate the calibration of single collector ICP-MS, instrument validation, as well as quality control.
  • Facilitate the acceptance of the technology and measurement infrastructure developed in the project by the measurement supply chain (e.g., accredited laboratories), standards developing organisations and international organisations and end users (e.g., environmental monitoring agencies).

Involved research facilities

Related publications

  • Poster
    10. RCA-Workshop, 12.-14.06.2023, Dresden, Deutschland

Permalink: https://www.hzdr.de/publications/Publ-36747