Transient flow maps for vertical pipe flow


Transient flow maps for vertical pipe flow

Lucas, D.

Experimental results concerning the development of the flow pattern for air-water flow in a vertical pipe of 51.2 mm inner diameter are presented. The data were obtained by a wire-mesh sensor. This allows a high resolution in space and time. 99 combinations of air and water superficial velocities were investigated in up to 10 different distances between the gas injection device and the sensor.

  • Lecture (Conference)
    5th Workshop on Measurement Techniques for Steady and Transient Multiphase Flows, Dresden, Germany, September 18-20, 2002

Permalink: https://www.hzdr.de/publications/Publ-4938