Bubble size distributions and three dimensional flow pattern visualization in stationary and transient upward flashing flow


Bubble size distributions and three dimensional flow pattern visualization in stationary and transient upward flashing flow

Manera, A.; Prasser, H.-M.; Lucas, D.; van der Hagen, T. H. J. J.

An experimental three-dimensional reconstruction and visualization of stationary and transient flashing flow in a vertical pipe (47 mm diameter) is presented. The measurements have been performed by means of wire-mesh sensors. This type of sensor delivers two-dimensional void fraction distributions in the pipe cross-section where it is mounted with a maximum sampling rate of 10,000 frames per second. A sampling rate of 1200 frames per second has been used in this work. Steam bubbles have been identified from the wire-mesh data and their complete three-dimensional reconstruction has been performed by taking into account the steam bubble velocity. For the estimation of the bubble velocity, two wire-mesh sensors positioned at a small axial distance from each other have been used. The velocity has been determined by cross-correlation of the two wire-mesh signals and by direct identification of the travelling time of the steam bubbles between the two sensors. A comparison between the two methods of bubbles velocity measurement is reported. Stationary and time-dependent bubble size distributions have been derived. The stationary radial void-fraction profiles have been decomposed according to bubble size classes and compared with the results obtained with an equilibrium model.

  • Contribution to proceedings
    3rd International Symposium on Two-phase Flow Modelling and Experimentation, 22.-24.09.2004, Pisa, Italy, Proceedings on CD-ROM, paper CVG10.

Permalink: https://www.hzdr.de/publications/Publ-6817