High-resolution measurements of the coolant mixing in the downcomer of the ROCOM test facility


High-resolution measurements of the coolant mixing in the downcomer of the ROCOM test facility

Kliem, S.; Prasser, H.-M.; Sühnel, T.

A new sensor was developed for an improved visualisation and quantification of the coolant mixing in the downcomer of the ROCOM test facility. This sensor spans a measuring grid of 64 azimuthal and 32 positions over the height of the downcomer On behalf of an experiment with the start-up of the main coolant pump the possibilities of the new sensor are demonstrated.

  • Contribution to proceedings
    Annual Meeting on Nuclear Technology 2006, 16.-18.05.2006, Aachen, Germany
    Proceedings, Berlin: Inforum GmbH, 78-84
  • Lecture (Conference)
    Annual Meeting on Nuclear Technology 2006, 16.-18.05.2006, Aachen, Germany

Permalink: https://www.hzdr.de/publications/Publ-7917