Prediction of countercurrent flow limitation and its uncertainty in horizontal and slightly inclined pipes


Prediction of countercurrent flow limitation and its uncertainty in horizontal and slightly inclined pipes

Murase, M.; Utanohara, Y.; Kusunoki, T.; Yamamoto, Y.; Lucas, D.; Tomiyama, A.

We proposed prediction methods for countercurrent flow limitation (CCFL) in horizontal and slightly inclined pipes with one-dimensional (1-D) computations and uncertainty of computed CCFL. In this study, we applied the proposed methods to a full-scale pressurizer surge line [inclination angle theta = 0.6 deg, diameter D = 300 mm, and ratio of the length to the diameter (L/D) = 63] in a specific pressurized water reactor, performed 1-D computations and three-dimensional (3-D) numerical simulations, and found that uncertainties caused by effects of the diameter and fluid properties on CCFL were small. We also applied the proposed methods to experiments for hot-leg and surge line models (theta = 0 and 0.6 deg, D = 0.03 to 0.65 m, and L/D = 4.5 to 63) to generalize them, performed 1-D computations, and found that uncertainties caused by effects of theta and L on CCFL were large due to the setting error for theta and differences among experiments. This shows that a small-scale air-water experiment with the same theta and L/D as those in an actual plant is effective to reduce the uncertainty of CCFL prediction.

Keywords: PWR hot leg; pressurizer surge line; countercurrent flow limitation

Permalink: https://www.hzdr.de/publications/Publ-25189