Imaging with gamma-ray computed tomography
During the last decade, two gamma-ray computed tomography (CT) setups, namely the high-resolution GammaCT system (HireCT) and the compact GammaCT system (CompaCT) were developed at the Helmholtz-Zentrum Dresden-Rossendorf.
|
|
The aim is to contactless expose two or multi-phase distributions in flows, occurring in technical apparatuses, operated under authentic industrial operating conditions, e.g. high pressures and high temperatures.
Parameters
| HireCT | CompaCT | |
| Number of scintillation detectors |
320 |
112 (2x4 mm² active areas) |
| Measurement method | energy discrimination / single photon counting | |
| Temperature stabilisation | 1 K | 1 K |
| maximum object diameter | 700 mm | 120 mm |
| Used isotopic source | Cs-137 (185 GBq) | Cs-137 (1,1 GBq) |
| Transportable | yes | yes |
| Digital signal processing | external | integrated |
more ...